USA-1 RESEARCH 400 ultrasonic wind sensor
A powerful tool for serious wind and turbulence studies

Links to previous pages
+ USA / Canada met index
      

Wind Section
  + wind FIND
     + wind type
        + wind ultrasonic
           + wind 3-axis
              -
YOU ARE HERE
             

 

FIND
by application


_______________

 

Send an e-mail to us  

Customized models are available, please email to discuss your requirements

_______________

The USA-1 Research 400 is a 3-axis ultrasonic wind sensor for the highly accurate measurement of horizontal and vertical wind speed and direction. With on-line turbulence calculations and the ability to connect additional sensors to produce a compact, portable station the Research 400 is ideal for use as part of an eddy-flux station.
   
CONTENTS ON THIS PAGE

OTHER LINKS

USA-1 Research 400 3-axis ultrasonic sensor.jpg

 


Features

  • separate measuring head and electronics which further reduces flow distortion and error
  • up to 50 Hz sampling rate
  • wind speed range 0 - 100 mph
  • digital and analog outputs
  • verifies and reports data quality
  • 6 external sensor inputs with time delay capability for time-modulated data output
  • 16 bit resolution on analog inputs
  • 4 analog channel outputs
  • 2 x TTL and 2 x PT100 inputs
  • on-line turbulence calculations
  • mains or battery power
  • field calibration kit
  • transport case

Top of page


What it does

The USA-1 Research 400 provides the following information in various data outputs which can be polled or output automatically:

  • instantaneous and averaged data for the three component wind vectors
  • virtual temperature
  • horizontal wind speed and direction plus vertical wind component
  • chart mode (provides 0-540º wind direction and speed values)
  • NMEA value outputs
  • raw data mode (uncorrected) or 2D / 3D head corrected data

Data can be averaged by several methods:

  • scalar or vectoral
  • clock synchronized or running average
  • separate output rates and sampling times

Some other important features:

  • user definable north orientation (range 0-359º alignment off axis)
  • data quality control to perform confidence checks on raw data
  • date / time stamps with several options
  • check sum information
  • calibration validity output monitoring

Near real-time turbulence calculations:

  • mean wind components (3D) and temperature
  • Standard Deviations (SD) of components and temperature
  • covariances of different components and temperature
  • SD values comparing mean wind to parallel component as well as the horizontally and vertically perpendicular wind component
  • turbulence intensities
  • friction velocity
  • Drag coefficient
  • Monin-Obukhov stability
  • momentum and heat fluxes
  • u, v, w
  • direction and velocity mean components or values

Top of page


Examples of data output

Normal data example (instantaneous). Every data string starts with a header line that consists of the string SNC followed by a space and 12 characters for the date/time stamp, another space and finally the UTC string i.e.:

SNC 940815090015 UTC

x = 1.83     y = -0.79    z = 0.20       T = 20.17     

Turbulence data example (averaged).The following lines display the averaged data using a fixed format: up to 4 values per line each preceded by its name (5 characters, right-aligned), a space character, an equals sign and an 8 character (right-aligned) floating point number with a fixed number of decimal digits (possibly with trailing zeros). This number will be replaced by 8 space characters in case of invalid data. The values are separated by a space character. The names of the data and their ordering can be understood from the following example:

SNC 940815090015 UTC    AVE  600      SMP  10    AZI  0      SDQ 100   HTR

x = 1.74 y = -0.93 z = -0.14 T = 0.62
xsig = 0.91 ysig = 0.89 zsig = 0.43 Tsig = 0.47
xycov = -0.3911 xzcov = -0.2010 xTcov = -0.1801
yzcov = 0.0961 yTcov = 0.2170 zTcov = 0.1200
psig = 1.07 qsig = 0.70 rsig = 0.40
tp = 0.54 tq = 0.35 tr = 0.20
ustar = 0.39 Tstar = 0.31 Cd = 0.04
MOs = -0.03 mf = -0.19 hf = 144.60
u = -0.93 v = 1.74 w = -0.14
vel = 1.98 dir = 151.9

_____________________________________________________________________

where:

AVE the averaging time
SMP the sampling rate in Hertz
AZI the devize azimuth
SDQ the sonic data quality
HTR informs the user that the sensor head heating is turned on
x mean x wind component in the sensor related orthogonal coordinate system (parallel to the black arrow on the electronic box); unit m/s
y mean y wind component in the sensor related orthogonal coordinate system (horizontally perpendicular to x); unit m/s
z mean z wind component in the sensor related orthogonal coordinate system (vertical); unit m/s
T mean temperature; unit ºC
xsig standard deviation of x; unit m/s
ysig standard deviation of y; unit m/s
zsig standard deviation of z; unit m/s
Tsig standard deviation of T; unit K
xycov covariance of x and y; unit m2/s2
xzcov covariance of x and z; unit m2/s2
xTcov covariance of x and T; unit mK/s
yzcov covariance of y and z; unit m2/s2
yTcov covariance of y and T; unit mK/s
zTcov covariance of z and T; unit mK/s
psig standard deviation of the wind component parallel to the mean wind direction; unit m/s
qsig standard deviation of the wind component horizontally perpendicular to the mean wind direction; unit m/s
rsig standard deviation of the wind component vertically perpendicular to the mean wind direction; unit m/s
tp longitudinal turbulence intensity
tq transversal turbulence intensity
tr vertical turbulence intensity
ustar friction velocity u.; unit m/s
Tstar characteristic temperature T.; unit K
Cd drag coefficient Cd
MOs Monin-Obukhov stability parameter; unit m-1
mf vertical momentum flux; unit kg/ms2
hf vertical heat flux; unit W/m2
u mean west-east wind component
(depends on setting of parameter AZ); unit m/s
v mean south-north wind component
(depends on setting of parameter AZ); unit m/s
w mean vertical wind component; unit m/s
vel mean horizontal wind velocity; unit m/s
dir mean horizontal wind direction
(depends on setting of parameter AZ); unit º


The following data strings will be displayed for the analog inputs/counters:

2 x PT100 inputs 6 x analog input channels 2 x TTL counters
e1 and e2 e3 to e8 c1 and c2
e1sig and e2sig e3sig to e8sig   
e1zco and e2zco e3zco to e8zco   

where:

2 x PT100 inputs
e1 and e2
   
mean Pt100 temperatures
(based on a0, a1 values of the basic system); unit ºC
e1sig and e2sig
  
standard deviations of the Pt100 temperatures
(based on a0, a1 values of the basic system); unit K
e1zco and
e2zco
covariances of the Pt100 temperatures
(based on a0, a1 values of the basic system) with z; unit Km/s
6 x analog inputs
e3 to e8
   
mean values of the analog input channels
(based on a2 ... a7 values of the basic system); unit V
e3sig to e8sig
  
standard deviations of the analog input channels
(based on a2 ... a7 values of the basic system); unit V
e3zco to e8zco
   
covariances of the analog input channels
(based on a2 ... a7 values of the basic system) with z; unit Vm/s
2 x TTL counters
c1 and c2 Counted events (based on c0, c1 values of the basic system); unit 1

 

Top of page


Specifications USA-1 Research 400 anemometer

Wind Speed  
Range 0 - 100 mph
Accuracy +/- 2 % (full scale output)
Resolution 0.01 m/s (steps)
Wind Direction  
Range 0 - 359o or 0- 540o
Accuracy +/- 2o
Resolution 0.4o (steps)
Digital Output  
Type RS232, RS422
Sampling rate 50 Hz
Averaging up to 3600 seconds
Analog Outputs x 4  
Type 0-5 V, 0- 10 V, 0-20 mA, 4-20 mA
Resolution 12 bit
Scalable Yes
Analog Inputs x 6  
Type +/- 2.5 V, +/- 5 V, +/- 10 V
Resolution 16 bit
Sample delay option Yes
PRT inputs 2
TTL inputs 2
PT100 inputs 2
Power  
Requirements 9-36 VDC or 115 / 230 VAC
Current draw 180 mA (@ 24 VDC)
Data  
Turbulence data Yes (see above for more information)
Sonic temperature :    
with digital output -22oF to 122oF (-30oC to 50oC)
in non-condensing environments
with analogue output measures within a 40o span (user configurable) of the above range with a resolution of 0.01oC
Units of measure m/s, knots, mph, km/h, oC
General  
IP rating 65
Size 12 x 27 inches
Weight 15 Ibs
Materials:  
              sensor head stainless steel (V4A)
                   electronic housing powder-coated die-cast aluminum

This range is in continuous development therefore
specifications may change without prior notice. E&OE

Accessories
I
ncluded with USA-1 Research 400:

Field Calibration Kit
Transport Case
Mains Adapter

65 ft power, data and analog cable  (26 ft between the measuring head and electronics box and 39 ft from electronics box)

Top of page


Delivery

This unit is usually dispatched within 6 - 8 weeks ARO (After Receipt of Order)

After Sales Support

Biral offers free advice and technical support for the lifetime of the instruments we sell. Once you have purchased the unit you can contact us for help on wwwusametsuppport@biral.com  


Search web site

 

 

 

 

 

Links to previous pages
+ USA / Canada met index
      

Wind Section
  + wind FIND
     + wind type
        + wind ultrasonic
           + wind 3-axis
              -
YOU ARE HERE
             

 

FIND
by application

Not sure if this is the right sensor for you and would like help selecting a sensor?

If you have not decided which sensor you would like or you would like to have a customized sensor incorporating features from more then one model please email wwwusamet@biral.com

or if you would prefer try the following pages:

   find sensors by application type
  

This range is in continuous development therefore specifications may change without prior notice. E&OE