SPECIFICATIONS
of this Reference Quality Weather Station
(WX90)
DATA LOGGER
Includes mounting hardware, PC Program for data
acquisition, data archiving, data presentation, lists, outputs, data exports from data
logger to PC from up to 5 different stations and 1m cable to connect data logger to PC.
WIND SPEED
Compact cup anemometer with mounting hardware.and heating.
Measuring range: 0.5 to 50 m/s.
Resolution: <0.1 m/ s
WIND DIRECTION
Compact vane anemometer with mounting hardware and
heating
Measuring range: 0 to 360 degrees
Accuracy: +/- 5 degrees
Resolution: 11.25o
HUMIDITY AND TEMPERATURE
Hygro-thermo transmitter and radiation shield for mounting
to mast
Measurement range: 0-100% RH, -30 to +70oC
Accuracy: +/-2 %(RH), 0.15oC (temp)
PRESSURE
BaroTransmitter for mounting in data logger enclosure
Measuring range: 800-1060 hPa
Accuracy: +/- 0.1 % of measuring range (20oC)
Operating temperature: -40 to 60oC
|