Command D1

<id>D1<para5> setting the function of the digital output 1 (opto-coupler)
Description see command table "D1" below
Value range 0...18
Initial value 13

 

Parameter Description Inactive (open) Active (closed) Frequency (Hz)

0

always inactive always

1

sensor error active no sensor error sensor error

2

sensor error inactive sensor error no sensor error

3

sensor in operation

50

4

sensor in operation
+ error


no error: 50
sensor error: 1

5

sensor in operation
+ precipitation
+ error


no error: 50
precipitation: 10
sensor error: 1

6

sensor in operation
+ liquid precipitation
+ solid precipitation
+ error


no error: 50
liquid precipitation: 25
solid precipitation: 10
sensor error: 1

7

precipitation active no precipitation precipitation

8

precipitation inactive precipitation no precipitation

9

liquid precipitation active no liquid precipitation liquid precipitation

10

liquid precipitation inactive liquid precipitation no liquid precipitation

11

solid precipitation active no solid precipitation solid precipitation

12

solid precipitation inactive solid precipitation no solid precipitation

13

precipitation quantity 0.1 mm

10 (1impulse: 0.1 mm)

14

precipitation quantity 0.01 mm

50 (1impulse: 0.01 mm)

15

precipitation quantity 0.005 mm

50 (1impulse: 0.005 mm)

16

always active
always

17

precipitation type SYNOP (Table 4680)
frequency output



see the following table for Parameter 17 (command D1 annd D2)

18

precipitation quantity 0.1 mm

1 (1impulse: 0.1 mm)

E&OE


Top of page


 

Parameter 17 (command D1 and D2)

Note: frequency output changes every minute

 

Parameter Frequency
(Hz)
SYNOP
(table 4680)
Description

0

1 -1 sensor error

1

5 0 no precipitation

2

10 51 light drizzle

3

20 52,53 moderate / heavy drizzle

4

25 41,42 unknown precipitation

5

33,33 57,61 light drizzle with rain, light rain

6

41,66 58,62,63 moderate / heavy drizzle with rain, moderate / heavy rain

7

50 67 light rain and / or drizzle with snow

8

62,5 68 moderate / heavy rain and / or drizzle with snow

9

83,33 77 snow grains

10

100 71 light snow fall

11

125 72,73 moderate / heavy snow fall

12

166,67 74,75,76 soft hail / ice grains

13

250 89 hail

Note: frequency output changes every minute

 